Wind & Solar Hybrid MPPT Controller – 12V/24V/48V

Code: F0808-HYBRID-WS-01

$127.65

5000 in stock

Product Description

Wind and solar hybrid MPPT controller for 12V/24V/48V off-grid systems with LCD, configurable load output and multiple protection functions.

15 People watching this product now!

Wind & Solar Hybrid MPPT Controller designed for small off-grid wind/solar systems, including hybrid street-light applications. The controller manages wind-generator and solar-panel charging to a battery system and provides configurable DC load output.

Functions and Features

  • Wind generator MPPT boost charging.
  • PWM wind dump-load control with external dump-load resistance and intelligent solar charging disconnection.
  • Dual power supply: battery + solar.
  • LCD displays wind, solar, battery and load voltage/current/power information; selected parameters are user configurable.
  • DC load output with three operating modes.
  • Controller circuit board uses conformal coating for resistance to dust, moisture and static electricity.

Safety Information

  • Inspect the product for transport damage before installation.
  • Installation and electrical work must be performed by qualified professional personnel.
  • Do not disassemble or attempt repairs without professional guidance.
  • Do not operate the controller without batteries.
  • Do not disconnect the controller from the batteries while the controller is operating normally.
  • Keep children away from the controller.
  • Do not allow water or snow to enter the controller.
  • Tighten all power connections and use cables suitable for the system to avoid excessive heating.

Protection Functions

Protection Description
Solar reverse-charging protection Prevents the battery from feeding current back into the solar panel when battery voltage is higher than PV voltage, such as at night.
Battery reverse-polarity protection Internal fuse protects the circuit when battery polarity is reversed; if the controller does not operate after correct reconnection, the fuse should be checked.
Battery open-circuit protection Protects the controller when the battery becomes open-circuit or poorly connected; battery connections should be checked regularly.
Over-voltage / over-current / over-load voltage protection Automatic braking and circuit protection are used to protect the wind generator, battery and output when limits are exceeded.
Lightning protection support In lightning-prone areas, the manual recommends dedicated external lightning-protection devices as part of a multilevel protection system; this is an optional additional requirement.

Physical Dimensions

  • Controller size: 167 x 145.5 x 61.8 mm.
  • Package size: 360 x 250 x 120 mm.
  • Net weight: 1.9 kg.
  • Gross weight: 2.3 kg.

Installation Notes

  • Read the installation instructions before mounting or wiring.
  • Disconnect all power sources before installing or adjusting the controller.
  • Keep the controller away from water, snow, corrosive gas and strong electromagnetic interference.
  • Choose a location that allows safe installation, electrical connection and later maintenance.

Wiring Sequence and Connections

  • Dump load: connect the external dump-load positive and negative terminals to the controller as indicated by the terminal markings.
  • DC load: connect load positive and negative correctly, avoid short circuit, and do not exceed the rated load current.
  • Battery: connect battery positive and negative correctly. The controller must not be operated without the battery connection.
  • Solar PV: connect PV positive and negative correctly. PV can produce hazardous voltage in sunlight; reverse polarity is prohibited.
  • Wind generator: connect the three wind-generator leads to the wind input terminals. For safer connection, connect in breeze or windless conditions; high-speed wind-generator connection should only be made while the controller is operating.

LCD and Operation

  • OK key: long press for more than 3 seconds to enter settings; use it to move to the next setting item; long press again to save parameters and exit.
  • Previous/Increase key: moves to the previous browsing item; in settings it increases the selected value, with long-press for faster adjustment.
  • Next/Decrease key: moves to the next browsing item; in settings it decreases the selected value, with long-press for faster adjustment.
  • Esc key: returns to the main browsing interface; in settings it moves to the previous setting item; long press for more than 3 seconds exits without saving.
  • If no key is pressed for approximately one minute during setting, modified parameters are not saved and the controller returns to the browsing interface.

Display Information

  • Battery voltage, battery capacity percentage, battery current, battery power and cumulative output.
  • PV voltage, PV current and PV power.
  • Wind-turbine voltage, current and power, including charging/braking indication.
  • Load operating mode, load power, load current and load fault code.
  • Controller temperature and temperature status code.
  • System-voltage status for 12V, 24V and 48V systems, including automatic-recognition modes.

Load and Temperature Codes

Code Meaning
L0 Normal
L1 Manual closing state
L2 Over-discharge protection
L3 Over-current protection
L4 Over-voltage protection
P0 Normal
P1 Low-temperature state
P2 High-temperature state
P3 Protection state
P4 Abnormal

Configurable Parameters

Item Setting Purpose / Options
1 System voltage Rated battery system voltage / automatic recognition.
2 Battery type b0 Custom; b1 Gel; b2 Ternary lithium; b3 Lithium iron phosphate.
3 LOW Over-discharge protection voltage.
4 RLOW Over-discharge recovery voltage.
5 FULL Over-charge protection voltage.
6 PV UL Light-control voltage used to identify day/night; approximately one-minute delay.
7 Solar ON/OFF Solar charge switch.
8 Wind ON/OFF Wind-turbine charge switch.
9 Load ON/OFF Load-output switch.
10 MODE Mode 1: light control; Mode 2: load always on at 100%; Mode 3: light control + time control with four adjustable time/power sections plus morning-light mode.
11-20 T1/P1, T2/P2, T3/P3, T4/P4, TC/PC Four timed load phases plus morning phase; each phase can be adjusted from 0 to 900 minutes and 0-100% power where applicable.

Battery Voltage Parameters

Battery type FULL – charging protection LOW – load disconnect RLOW – load reconnect
Custom (b0) 14.4 / 28.8 / 57.6 V adjustable 10.5 / 21.0 / 42.0 V adjustable 12.5 / 25.0 / 50.0 V adjustable
Lead-acid / Gel (b1) 14.4 / 28.8 / 57.6 V default 10.5 / 21.0 / 42.0 V default 12.5 / 25.0 / 50.0 V default
Ternary lithium (b2) 12.6 / 25.2 / 54.6 V default 9.0 / 18.0 / 39.0 V default 10.0 / 20.0 / 43.4 V default
Lithium iron phosphate (b3) 14.4 / 28.8 / 57.6 V default 10.0 / 20.0 / 40.0 V default 12.0 / 24.0 / 48.0 V default

Technical Specifications

Parameter Specification
Rated system voltage 12V, 24V, 48V, 12/24V AUTO, 24/48V AUTO
Maximum input voltage – 12/24V system Wind turbine <= 80V; solar panel <= 55V
Maximum input voltage – 48V system Wind turbine <= 80V; solar panel <= 95V
No-load current (DC) <= 0.05A
Controller power mode Battery or solar
Control mode Wind-generator MPPT boost charge, PWM dump load, PWM over-current limiting
Load operating modes Three adjustable modes: light control; always on; light + time control
Display LCD: voltage, battery percentage, current, load working mode and related system status
Cooling Aluminium-profile heat dissipation and self-cooling
Working temperature -25 C to +80 C
Relative humidity 0-90%, non-condensing
Net / gross weight 1.9 kg / 2.3 kg
Controller / package size 167 x 145.5 x 61.8 mm / 360 x 250 x 120 mm

FAQ from Supplier Manual

Question Answer
Wind generator becomes very slow immediately after connection Possible causes listed in the manual: battery has reached floating voltage; wind-generator rated output voltage is much higher than the battery and its speed is pulled down by battery voltage; or the dump-load MOS may have been damaged by incorrect operation.
Why does the wind generator dump load when only a small current is displayed? The controller protects the system based on battery voltage, charging current, temperature and other conditions. It may activate dump load at floating voltage or high temperature regardless of displayed charging current.
LCD does not display Check the battery-to-controller connection. If the battery is damaged, check and replace it.
No charging current Charging occurs only when the solar-panel or wind-generator input voltage is higher than the battery voltage.

Supplier Manual Warranty Statement

The supplied manual states a one-year warranty from shipment to the original end user for normal-use failures, with repair or replacement during the warranty period and paid repair service outside the warranty period. It also states that warranty coverage does not apply to damage caused by operation contrary to the manual, accident/negligence/abuse, unauthorized modification or attempted repair, or shipment damage. Warranty terms should be confirmed with YASERBABA at the time of order.

Manual reference: FYVIP260808.

YASERBABA